Conduction Analysis of a Single Material Cylinder



Experimental Procedure

  1. Install the insert 1 adjust the cooling water flow rate(only a very low cooling water flow rate of apporximately  1liter/hour is requied to  dissipate a heater power 90w at a temp difference of 90 0 c).

  2. Switch on the unit and adjust the power to 40w usinh the potentimeter of the control and dispaly unit.

  3. When the thermal conduction process has reached a steady state condition,i.e. the temperature at the individual measuring points are stable and no longer changing,note the temperatures at various locations and the power supplied to the heater.

  4. The same procedure holds good for all the inserts and for the liner and radial conduction.

Virtual Experimentation Procedure

  •   TO RUN THIS EXPERIMENT CLICK RUN BUTTON INDICATED AS AN ARROW

INPUT PALETTE :

1.   Select one of the Material from Listhen automatically Conductivity K shows of selected material.

2.    Enter cold End.

3.    Enter Hot End.

4.    Enter Inner Radius.

5.    Enter Outer Radius.

1. Green color Bubble is blinking (in Yellow color) means process is start.

 


          

OUTPUT PALETTE:

OUTPUT PALETTE shows Temperature v/s Distance Graph.